End Position Damping
In the case of end position damping, the kinetic energy is converted to heat energy. At a constant delay, the following applies:
m 2 | v² | = A |
m | = | moving mass | (kg) |
---|---|---|---|
v | = | Travel speed | [m/s] |
A | = | Effective damping area | [m²] |
p | = | Average damping pressure | N m² |
s | = | Damping distance | [m] |
this results in the average damping pressure:
p | = | m * v² 2 * A * s |